ALKALITE R
Alkalite resolves problems involving
low pH and corrosive
carbonic acid.
Swedish-made. Free of chemical additives.
Swedish-made. Free of chemical additives.
Download:
Technical data
Max. pressure/PN: 6 bar
Pump starts per 24 hours: 15 starts max.
Operating temperature: max 40 °C
Drain for backwashing required: Yes
Electrical connection for automation: 230 V 50 Hz
Product options
- Time-controlled automation or manual backwash
- Ecoflush air injector reduces the backwash volume
– a drain-friendly option.
Included in delivery
- Alkalite R with service-friendly stainless steel
filter housing (20-year warranty) - Time-controlled automation or manual backwash
- Filter medium
Functional description
The water flows into the filter via a pressure tank or membrane pressure tank and passes through the filter medium consisting of lime (half-burnt dolomite).
In the filter medium, the corrosive carbonic acid is neutralised and the pH value rises. The pH value is regulated to the desired value using the filter’s integrated mixing valve.
Backwashing via the automation or manual valves ensures that the filter medium is agitated, preventing it from solidifying.
Technical data
- Max. pressure/PN…………………………………….. 6 bar
- Pump starts per 24 hours:……………………….15 starts max.
- Operating temperature:………………………….max 40 °C
- Drain for backwashing required……………………Yes
- Electrical connection for automation…………….230 V 50 Hz
Download:
Layout diagram

2. Pressure switch
3. Pressure tank/membrane pressure tank
4. Alkalite-R
Rate (m/h) | < 18 | Intermittent | Flushing flow | Air | |
Model | l/min | l/min* | l/min | l/min | |
Alkalite R12 | 21 | 39 | 36 | 22 | 14 |
Alkalite R16 | 38 | 64 | 50 | 34 | 16 |
*Applies to intermittent draining of vessel volume for 2 minutes in combination with 150-litre pressure tank
with Ecoflush air injector (option)
Dimensions, mm | |||||
Model | Item no. | Height | Width | Depth | Connection |
Alkalite R12 | 520270 | 1300 | 385 | 385 | G20 |
Alkalite R16 | 520275 | 1580 | 475 | 475 | G20 |