IRON- & MANGANESE FILTERS

GÖINGEFILTER KOMBI AUL

Combination filter with additional reservoir control
that resolves problems involving iron and manganese
– as well as low pH, corrosive carbonic acid and
hydrogen sulphide/sewer gas.

Swedish-made. Free of chemical additives.

Combination filter with additional reservoir control that resolves problems involving iron and manganese
– as well as low pH, corrosive carbonic acid and hydrogen sulphide/sewer gas.

Swedish-made. Free of chemical additives.

Download:

Technical data

Max. pressure/PN: 6 bar
Pump starts per 24 hours: 15 starts max.
Operating temperature: max 40 °C
Drain for backwashing required: Yes
Electrical connection for automation: 230 V 50 Hz

Product options

  • Time-controlled automation or manual backwash
  • Ecoflush air injector reduces the backwash volume
    – a drain-friendly option.

 

Included in delivery

  • Göingefilter AUL, service-friendly stainless steel
    filter housing (20-year warranty)
  • Time-controlled automation or manual backwash

Functional description

The water passes through the air pocket in the upper part of the filter, with iron and manganese being precipitated as solid particles and filtered out. The upper layer of the bed neutralises the carbonic acid (CO2) and alters the pH value.

The process is repeated using the external circulation via the return line from the reservoir, and multi-filtered water is obtained. This has the advantage that large amounts of iron and manganese can be filtered out via the slow flow of the circulation.

Once the filter bed is saturated, the filter is backwashed in the opposite direction. Once backwashing is complete, the system enters filtration mode via the automation.

Also available in a manual backwash version.

Technical data

  • Max. pressure/PN…………………………………….. 6 bar
  • Pump starts per 24 hours:……………………….15 starts max.
  • Operating temperature:………………………….max 40 °C
  • Drain for backwashing required ………………………Yes
  • Electrical connection for automation……………… 230 V 50 Hz

Download:

Layout diagram

1. Water in
2. Pressure switch
3. Pressure tank/membrane pressure tank
4. Göingefilter Kombi AUL
5. Low reservoir
6. Multi-filtration pump
7. Pump to dwelling
Rate (m/h)181512105*IntermittentFlushing flowAirBackwash volume
Fe+Mn (ppm)< 2,5< 3,5< 5,0< 7,0< 10,0
Modell/minl/minl/minl/minl/minl/minl/minl/minl/minl/minl/min
Kombi 125 AUL403327221165503416750340

* cirkulation

with Ecoflush air injector (option)

Dimensions, mm
ModelItem no.HeightWidthDepthIndex g/m³Connection
Kombi 125 AUL520055153065046050G20